Industrial Automation, Marine Automation, Engine Control and Safety Systems, Dynamic Positioning Systems, Fire Alarm and Safety Equipment, Engine Remote Control System

MOBREY MCU201 LIQUID-LEVEL-CONTROLLER 115-230VAC


BRAND: Mobrey

CONDITION: New - Open Box

SKU: 3751SA

MOBREY MCU201 LIQUID-LEVEL-CONTROLLER 115-230VAC (NEW WITHOUT BOX)


MOBREY LTD 

LIQUID-LEVEL-CONTROL

MODEL.NO: MCU201

SERIES: MCU200

VOLTAGE: 115/230VAC 6VA


THE MCU CONTROLLER AND GAP SENSOR WHEN USED TOGETHER PROVIDE AN ULTRASONIC POINT LEVEL LIQUID SWITCH. TYPICAL APPLICATIONS INCLUDE SLUDGE BLANKET LEVEL DETECTION IN SETTLEMENT TANKS, INTERFACE DETECTION FOR IMMISCIBLE LIQUIDS AND CONTAMINATION DETECTION, SUCH AS OIL IN WATER OR WATER IN OIL. THE MCU201 AND MCU203 CONTROL UNITS PROVIDE SIMPLE AND ECONOMICAL CONTROL ELECTRONICS FOR WALL-MOUNTING NEAR A TANK OR PIPELINE CONTAINING A SINGLE ULTRASONIC GAP SENSOR. THE SENSORS OPERATE ON THE ATTENUATION OF AN ULTRASONIC SIGNAL THROUGH THE FLUID. VIEW OUR WEBINAR FEATURING THE MCU200.


FEATURES & BENEFITS:

 

• WALL-MOUNTING IP65 POLYCARBONATE ENCLOSURE

• DPDT RELAY OUTPUT FOR WET-TO-DRY OR DRY-TO-WET CHANGEOVER INDICATION, EXTERNAL CONTROL, OR ALARM CONDITION INDICATION.

• ACCEPTS A VOLTAGE-FREE CONTACT INPUT E.G. TO ACTUATE A PUMP CONTROL FUNCTION VIA THE OUTPUT DPDT RELAY

• THREE LED INDICATORS – NORMAL, ALARM, AND FAULT

• SELECTABLE TIME DELAY (0.5, 2, 8 OR 30 SECONDS) FOR WET-TO-DRY OR DRY-TO-WET CHANGEOVER

• CONTINUOUS CABLE CHECK BETWEEN CONTROLLER AND MOBREY 400SD POINT LEVEL DETECTOR

• CHOICE OF SENSORS FOR USE IN TANKS AND PIPELINES


KEY FEATURES:


• ULTRASONIC TECHNOLOGY

• LEVEL OR INTERFACE DETECTION

• OIL IN WATER OR WATER IN OIL DETECTION

• CHOICE OF SENSORS FOR TANKS OR PIPES

• LED INDICATION FOR NORMAL, ALARM AND FAULT

• DPDT RELAY OUTPUT, CONFIGURABLE FOR WET TO DRY, OR DRY TO WET

CHANGEOVER

• CABLE CHECK FAULT DETECTION

• SELECTABLE TIME DELAY

• UNAFFECTED BY LIQUID COLOUR/OPACITY, OR CONDUCTIVITY

• WALL MOUNTING IP65 POLYCARBONATE ENCLOSURE


TECHNICAL SPECIFICATION: 


POWER SUPPLY: 110/220 VAC OR 220/240 VAC SELECTABLE

POWER CONSUMPTION: 6VA

NUMBER OF SENSOR INPUTS: ONE

RELAY OUTPUT: DOUBLE-POLE CHANGEOVER (DPDT)

ENERGISED WHEN SENSOR IS WET OR DRY (CONFIGURABLE)

RELAY RATING: 5A AT 230V

ENCLOSURE SIZE: 200 X 120 X 75MM (7.9 X 4.7 X 3.0 INCHES)

ENCLOSURE RATING: IP65 POLYCARBONATE

HOLES FOR GLANDS: 3 OFF 16MM (0.63 INCHES)

FIXING CENTERS FOR WALL MOUNT: 188 X 88MM W X H (7.4 X 3.4 INCHES)

FIXING HOLE DIAMETER: 4MM (0.16 INCHES)

FREQUENCY SELECTION: 1 MHZ (HIGHER SENSITIVITY) OR 3.7 MHZ (STANDARD) BY SWITCH

LED INDICATORS: GREEN FOR NORMAL. RED FOR ALARM. AMBER FOR FAULT. VISIBLE THROUGH LID.

GREEN OR RED SELECTABLE FOR WET OR DRY.

GAIN SETTING: RANGE SWITCH AND GAIN POTENTIOMETER TO ADJUST FOR SENSOR AND APPLICATION

RESPONSE TIME: SELECTABLE DELAY OF 0.5, 2, 8 OR 30 SECONDS

DELAY SELECTABLE FOR WET-TO-DRY OR DRY-TO-WET CHANGEOVER

50MS RESPONSE IN OPPOSITE DIRECTION

SENSOR CABLE CHECK: SELECTABLE TO MONITOR COAX SCREEN FOR CONTINUITY

FAULT CONDITION LIGHTS THE FAULT LED AND SETS RELAY TO ALARM STATE

AUXILIARY INPUT: EXTERNAL CLOSED CIRCUIT INPUT LATCHES THE OUTPUT RELAY TO ACHIEVE PUMP CONTROL


REF: FKM3751SA


100% Genuine Product | You will get what you see in pictures.

Related Products